Product Features
KH-DK/DC10V200A, input AC110V ± 10%, output voltage DC10, output current 200A, total power 2000W, adjustable voltage and current, LAN interface, supporting SCPI communication protocol.
Main technical indicators
| Model | KH-SK/DC6V800A |
| Working Method | Automatic switching between stable voltage and current states |
| Input | AC380V±10% 50Hz±10% |
| Output | Continuous adjustable range of constant voltage value: 0~6V |
| Continuous adjustable range of constant current value: 0~800A |
| Voltage Stability Accuracy | Source Effect | ≤ 0.3% rated value (rate of change in output voltage caused by ± 10% variation in input voltage) |
Load Effect | ≤ 0.2% rated value (output voltage change rate caused by load variation from 10% to 90%) |
Time Drifting | ≤ 0.2% rated value (output voltage change rate caused by continuous working time greater than 8 hours) |
Temperature Drift | ≤ 0.03% rated value/℃ (due to the output voltage change rate caused by ambient temperature within the temperature range of power supply use) |
| Voltage Stability Accuracy | Source Effect | ≤ 0.5% rated value (output current change rate caused by input voltage variation of ± 10%) |
Load Effect | ≤ 0.3% rated value (rate of change in output current caused by load variation from 10% to 90%) |
Time Drifting | ≤ 0.3% rated value (output current change rate caused by continuous working time greater than 8 hours) |
Temperature Drift | ≤ 0.05% rated value/℃ (due to the rate of change in output current caused by ambient temperature within the temperature range of power supply use) |
| Ripple (r.m.s) | ≤ 0.3% (output at rated voltage) |
| Voltage/Current Setting | Button+Knob Setting |
| Display Function | Display Mode | The voltmeter displays on a 4-digit LCD screen The ammeter displays on a 4-digit LCD screen. |
Display Resolution | Voltage meter 0.1V, current meter 0.01A |
Display Error | Voltage meter ≤ 0.5% ± 1 word, current meter ≤ 0.5% ± 1 word (within 10% -100% range) |
| Protection Method | Output current limiting, voltage limiting, short circuit, overvoltage, overload protection |
| Program Control and External Control Methods | LAN interface, supporting SCPI communication protocol |
| Power Size | W430*H88*L500 /Unit: mm |
| Working Method | Long term full load continuous work |
| Operating Temperature | -25℃~+50℃; Relative humidity<80% |
| Insulation Resistance | ≥20MΩ |
| Compressive Strength | 1500V 60S |