30 V 20 A linear DC power supply
Product Features
30V20A linear DC power supply, output voltage 30V, output current 20A, continuously adjustable; The stable voltage and current state can be automatically switched, and the output ripple is ≤ 0.03% of the rated value.
Technical Parameters Of Linear DC Power Supply (KH-DX/DC30V20A)
| Input Voltage | AC 220V ± 10% ,50Hz ± 10% |
Stable Voltage and Current | The voltage and current values can be continuously adjusted from 0 to the rated value, and the stable voltage and current state can be automatically switched |
Voltage Regulation Accuracy | Source effect: ≤ 0.03% rated value (the rate of change in output voltage caused by a ± 10% change in input power supply voltage) Time drift: ≤ 0.2% of rated value (the rate of change in output voltage caused by continuous operation of the power supply for more than 8 hours) Temperature drift: ≤ 0.03% rated value/℃ (the rate of change in output voltage caused by changes in ambient temperature within the range of power supply usage) Load effect: ≤ 0.03% (rate of output voltage change caused by the change of power output current from zero to rated value) |
Steady Current Accuracy | Source effect: ≤ 0.03% rated value (rate of change in output current caused by ± 10% variation in input power supply voltage) Time drift: ≤ 0.2% of rated value (rate of change in output current caused by continuous operation of the power supply for more than 8 hours) Temperature drift: ≤ 0.03% rated value/℃ (the rate of change in output current caused by changes in ambient temperature within the range of power supply usage) Load effect: ≤ 0.03% (rate of change in output current caused by the change in power output voltage from zero to rated value) |
Output Ripple | ≤ 0.03% rated value (measuring range: 80% to 100% rated output) |
Voltage/Current Setting | Ten turn potentiometer; |
Display Mode | Voltage and current meter LED digital display; |
Display Resolution | LED: Voltage meter 0.1V, current meter 0.001A (note: display accuracy may vary for different specifications of power supply) |
Whole Machine Error | Voltage meter ≤± 0.1% ± 1 word (measuring range 5%~100% rated value) Ammeter ≤± 0.1% ± 1 word (measuring range 5%~100% rated value) |
Short circuit protection | Allow short circuit and alarm |
Protection method | Automatic protection against overvoltage and overcurrent |
Working method | Long term full load continuous work |
Environmental conditions | Temperature -20 ℃~+40 ℃, humidity ≤ 80% |
Communication Method | Analog quantity: 0-10V control voltage and current output signals are controlled by external dry contacts. When closed, the output is turned off; when disconnected, the output is turned off. At the same time, abnormal output signals are matched |