1000 V 10 A DC Power Supply
Product Features
KH-SK/DC1000V10A, 10kw high-power DC power supply, input AC380V ± 10%, output voltage DC1000V, output current 10A, total power 10KW, adjustable voltage and current, supports RS485 programmable control.
Main Technical Indicators
| Model | KH-SK/DC1000V10A(10KW) | |
| Working Method | Automatic switching between stable voltage and current states | |
| Input | AC380V±10% 50Hz±10% | |
| Output | Continuous adjustable range of constant voltage value: 0~1000V | |
| Continuous adjustable range of constant current value: 0~10A | ||
Voltage Stability Accuracy | Source Effect | ≤ 0.3% rated value (rate of change in output voltage caused by ± 10% variation in input voltage) |
Load Effect | ≤ 0.2% rated value (output voltage change rate caused by load variation from 10% to 90%) | |
Time Drifting | ≤ 0.2% rated value (output voltage change rate caused by continuous working time greater than 8 hours) | |
Temperature Drift | ≤ 0.03% rated value/℃ (due to the output voltage change rate caused by ambient temperature within the temperature range of power supply use) | |
Voltage Stability Accuracy | Source Effect | ≤ 0.5% rated value (output current change rate caused by input voltage variation of ± 10%) |
Load Effect | ≤ 0.3% rated value (rate of change in output current caused by load variation from 10% to 90%) | |
Time Erifting | ≤ 0.3% rated value (output current change rate caused by continuous working time greater than 8 hours) | |
Temperature Drift | ≤ 0.05% rated value/℃ (due to the rate of change in output current caused by ambient temperature within the temperature range of power supply use) | |
| Ripple (r.m.s) | ≤ 0.3% (output at rated voltage) | |
| Voltage/Current Setting | Button+Knob Setting | |
| Display Function | Display Mode | The voltmeter displays on a 4-digit LCD screen The ammeter displays on a 4-digit LCD screen. |
Display Resolution | Voltage meter 0.1V, current meter 0.01A | |
Display Error | Voltage meter ≤ 0.5% ± 1 word, current meter ≤ 0.5% ± 1 word (within 10% -100% range) | |
| Protection Method | Output current limiting, voltage limiting, short circuit, overvoltage, overload protection | |
| Program Control and External Control Methods | Connect directly to the PC through CAN, RS485, 232, LAN interfaces, control the output voltage and current values through dedicated software, and monitor the working status of the power supply in real time on the computer to accurately grasp the load characteristics. | |
| Power Size | W* H* L (430 * 132 * 550)/Unit: mm | |
| Working Method | Long term full load continuous work | |
| Operating Temperature | -25℃~+50℃; Relative humidity<80% | |
| Insulation Resistance | ≥20MΩ | |
| Compressive Strength | 1500V 60S | |